The Vision · Water Harvesting

Harvest the flood, not the river.

Water is one key to the MMC design. Flood overflow is captured at scale, pumped on power from the desert solar farms, stored, and moved on the elevated corridor where it is needed, without damming or draining the rivers. It is a national transfer system for the whole nation.

Water allows the rest.

The towns, the PV farming, the data centres and the industry along the corridor all need water. Harvesting it and moving it on the corridor is what opens the land.

Three ways to capture the flood.

Water is taken only in high-flow and flood events. Nothing is built across the river channel.

  1. Off-channel ring tank. Tanks on the floodplain beside the river fill only in major floods; pumps then lift the water into the feeder aqueduct. No wall across the river.1
  2. River threshold pumping. A pump station on the bank with a set flow level: it runs above the threshold and stops below it. Nothing is built in the channel.1
  3. Inland flood capture. Overflow weirs or threshold pumps on inland channels that run only in mega-floods, feeding the nearest corridor line.1
MMC WATER · WATER HARVESTING TAKE THE FLOOD, NOT THE RIVER · MMC-VC OPEN AQUEDUCT · POWER FROM THE DESERT SOLAR PV, CARRIED ON THE AQUEDUCT · STORAGE DAMS AND PUMPED HYDRO A · THE SYSTEM: FROM FLOOD TO STORAGE FEEDER AQUEDUCT · MMC-VC MMC MAIN LINE · AQUEDUCT River in flood Flood water spreads over the floodplain; normal flow stays in the channel. Pump station Runs above the flow threshold only Open aqueduct channel Water carried by gravity on the MMC-VC deck Power line from the desert solar PV Carried on the aqueduct to every pump site Wetland: crossed from the deck No ground access road; only the pylon footprints touch the ground. Flow threshold Upper storage Storage dams: pumped hydro A water battery: pumped up on surplus solar, released through turbines when power is needed. Storage dam Supply by gravity Towns, farms, industry, data centres Desert solar PV continues B1 OFF-CHANNEL RING TANK Fills only in major floods. No wall across the river. MMC-VC aqueduct Flood over the floodplain Flood overflows the sill into the tank Ring tank River channel: untouched Pump lifts stored flood water into the aqueduct. B2 RIVER THRESHOLD PUMPING Bank pump runs above the flow threshold only. MMC-VC aqueduct Flow threshold Set for each site by hydrological assessment. Below it, the pump stops automatically. Flood flow: harvested Normal flow: stays in the river B3 INLAND FLOOD CAPTURE Overflow weir or threshold pump on inland channels. MMC-VC aqueduct Inland channel in flood Overflow weir Dry in most years: water is captured only in mega-floods. Sump Flood flow Normal flow / stored water Precast concrete Pump Power from the desert PV Flow threshold Pumping runs in flood season only, above each site's flow threshold; the system is idle for six to eight months a year. The solar PV is in the desert zones. The aqueduct carries the power line to every pump site. Harvested water is moved to storage dams, ideally pumped hydro. MMC-VC open aqueduct shown; pipe options for detailed design. Capture types from MMA Memo 14, The Sovereign Aqueduct Network. Schematic, not to scale.
The three capture types. Each pump lifts into an MMC-VC open aqueduct and is powered from the line carried on the aqueduct. Schematic, not to scale.

The river keeps its flow.

Built into sensitive country, from the deck.

MMC WATER · BUILT FROM THE DECK NO GROUND ACCESS ROAD · THE CORRIDOR IS BUILT FORWARD FROM THE COMPLETED DECK · ONLY THE PYLON FOOTPRINTS TOUCH THE GROUND A · THE WORK FRONT: A WETLAND CROSSED FROM THE DECK 25 m to the next pylon 1 · COMPLETED: AQUEDUCT IN SERVICE 2 · THE DECK IS THE ROAD 3 · WORK FRONT 4 · AHEAD: UNTOUCHED MMC-VC open aqueduct on the completed spans Power line carried on the aqueduct Supply train on the finished deck: pylon rings, beams, channel sections Rail crane on the completed deck Derrick lowered from the deck drills the next foundation Umbilical: power and hydraulics No access road. No cleared strip. Future pylon positions Water and wildlife pass under the spans Only the pylon footprints touch the ground Dry bank Wetland B1 GROUND PIPELINE: SECTION ACROSS THE ROUTE A buried pipe needs a road beside it to be built and maintained. Continuous footprint: embankment, road and cleared strip Access road Buried pipe Flow across the wetland is blocked Embankment across the wetland B2 MMC-VC ELEVATED AQUEDUCT: SECTION ACROSS THE ROUTE Built and maintained from the deck. The wetland continues underneath. Footprint: one pylon every 25 m Open aqueduct channel Power line Flow across the wetland continues Wetland water Water in the aqueduct or pipe Precast concrete Crane, derrick, locomotive Embankment Power line The corridor is built forward from the completed deck. Materials arrive along the deck, so no road is cut into the wetland, river or forest below. A rail crane on the finished deck lowers a derrick to the next pylon position, 25 m ahead, and drills the foundation in place (MMC-DWG-003-05). Build scenarios along a whole route, and the six-step deck cycle, are on MMC-DWG-003-13. Ravines and tall pylons: detailed design. The ground pipeline in B1 is a generic comparison, not a specific project. Schematic, not to scale.
A wetland crossed from the deck. Materials arrive along the finished deck; a rail crane lowers a derrick to the next pylon position, 25 m ahead. Below: a ground pipeline with its embankment and access road, and the MMC-VC elevated aqueduct. MMC-DWG-009-02. Schematic, not to scale.

Drawing: drilling from the viaduct →   Drawing: build scenarios along a route →   Environment: the lowest-impact system →

Desert sun pumps the water.

MMC WATER · SYSTEM MAP: MOCK SCENARIO FEEDER AQUEDUCTS FAN OUT TO THE RIVER SYSTEMS · ONE MAIN LINE TO THE DRY INTERIOR · SOLAR AROUND EACH TOWN POWERS EVERY PUMP · FARMING UNDER THE PV long distance P P P P P WET NORTH · FLOOD RIVERS DRY INTERIOR DESERT SEA River A River B River C River D Inland river E Inland floodplain B1 · Off-channel ring tank B2 · River threshold pumping B2 · River threshold pumping B1 · Off-channel ring tank B3 · Inland flood capture Junction: the feeders join the main line MMC-VC feeder aqueducts MMC-VA main line Pumped hydro: upper and lower reservoir, penstock Pumped hydro Storage dam Storage dam Storage dam Power line on the aqueduct to every pump Solar PV ring with farming underneath Town centre Town Town City at the corridor intersection Towns spaced along the corridor to the next town to the next town 1 2 3 4 5 6 7 N River Flood extent Aqueduct, flow arrowed Power line Pump station Solar PV rows Farming under the PV Pumped hydro 1 Wet-season floods run down the northern rivers to the sea. 2 Capture sites take a share of the flood peak (types B1, B2, B3 on MMC-DWG-009-01). 3 MMC-VC feeder aqueducts fan out from one junction to each river system. 4 The MMC-VA main line carries the water to the dry interior. 5 Storage dams and pumped hydro on the lines keep flood water and store surplus power. 6 The solar PV ring around each town sends power along the aqueduct to every pump. 7 Towns are spaced along the corridor. Each has a town centre inside a solar PV ring, with farming under the PV. A city stands where two lines intersect. Mock scenario: the rivers, sites and layout are invented. Not a route proposal. Not to scale.
A mock scenario seen from above. 1 Flood rivers. 2 Capture sites. 3 Feeder aqueducts fan out from one junction. 4 Main line to the dry interior. 5 Storage dams and pumped hydro. 6 The solar PV ring around each town, with farming under the PV, powers every pump. 7 Towns spaced along the corridor. The rivers, sites and layout are invented. MMC-DWG-009-03. Not to scale.

PV / Farming →

From the flood to storage, by gravity to the user.

  1. Capture. Flood overflow only, above each site's threshold.
  2. Feeder aqueduct. An MMC-VC open aqueduct, elevated, from the capture site to the nearest MMC corridor.
  3. Main line. MMC-VA is the main water line, about 10,000 GL a year per line (planning figure); MMC-VB also carries water in smaller pipes.
  4. Storage dams. The harvested water is moved into storage dams, ideally pumped hydro water batteries: stored high, released through turbines when power is needed.
  5. Supply. Delivered by gravity from storage to towns, farms, industry and data centres.
MMC WATER · WATER HARVESTING TAKE THE FLOOD, NOT THE RIVER · MMC-VC OPEN AQUEDUCT · POWER FROM THE DESERT SOLAR PV, CARRIED ON THE AQUEDUCT · STORAGE DAMS AND PUMPED HYDRO A · THE SYSTEM: FROM FLOOD TO STORAGE FEEDER AQUEDUCT · MMC-VC MMC MAIN LINE · AQUEDUCT River in flood Flood water spreads over the floodplain; normal flow stays in the channel. Pump station Runs above the flow threshold only Open aqueduct channel Water carried by gravity on the MMC-VC deck Power line from the desert solar PV Carried on the aqueduct to every pump site Wetland: crossed from the deck No ground access road; only the pylon footprints touch the ground. Flow threshold Upper storage Storage dams: pumped hydro A water battery: pumped up on surplus solar, released through turbines when power is needed. Storage dam Supply by gravity Towns, farms, industry, data centres Desert solar PV continues B1 OFF-CHANNEL RING TANK Fills only in major floods. No wall across the river. MMC-VC aqueduct Flood over the floodplain Flood overflows the sill into the tank Ring tank River channel: untouched Pump lifts stored flood water into the aqueduct. B2 RIVER THRESHOLD PUMPING Bank pump runs above the flow threshold only. MMC-VC aqueduct Flow threshold Set for each site by hydrological assessment. Below it, the pump stops automatically. Flood flow: harvested Normal flow: stays in the river B3 INLAND FLOOD CAPTURE Overflow weir or threshold pump on inland channels. MMC-VC aqueduct Inland channel in flood Overflow weir Dry in most years: water is captured only in mega-floods. Sump Flood flow Normal flow / stored water Precast concrete Pump Power from the desert PV Flow threshold Pumping runs in flood season only, above each site's flow threshold; the system is idle for six to eight months a year. The solar PV is in the desert zones. The aqueduct carries the power line to every pump site. Harvested water is moved to storage dams, ideally pumped hydro. MMC-VC open aqueduct shown; pipe options for detailed design. Capture types from MMA Memo 14, The Sovereign Aqueduct Network. Schematic, not to scale.
The system from flood to storage: river in flood, pump station, MMC-VC open aqueduct over the wetland, storage dam and upper storage as pumped hydro, supply by gravity, and the desert solar PV with its power line carried on the aqueduct. Schematic, not to scale; pipe options for detailed design.

The Aqueduct MM Line →   The Water MM Line →

The MMA plan: northern floods to the centre.

Northern runoff
>200,000 GL/yr

Reaches the ocean; about 94% arrives as wet-season flood pulses.1

Target capture
30,000 GL/yr

About 12–15% of northern coastal runoff, taken only as flood overflow.1

Australia's use today
~70–80,000 GL/yr

Total urban and rural use; the target is under half of it.1

Storage
Alice Hub

About 550 m elevation in central Australia, with gravity delivery south and no large northern dams.1

MMC WATER · AUSTRALIA: THE MMA PLAN NORTHERN FLOODS TO THE CENTRE · STORED AT THE ALICE HUB · DELIVERED SOUTH BY GRAVITY · CORRIDORS LINK THE PORTS AND CITIES Darwin Derby Port Hedland Perth Albany Esperance Adelaide Melbourne Sydney Newcastle Brisbane Mackay Port Douglas Karumba Canberra Geraldton Carnarvon Karratha Kalgoorlie Mount Isa Albury City 1 City 2 City 3 City 4 ALICE HUB · ~550 m Lake Argyle Fitzroy Ord Victoria Daly Roper Mitchell Gilbert Flinders Georgina Diamantina Cooper Creek Finke Lake Eyre Murray Darling Murrumbidgee Lachlan Burdekin Gascoyne Murchison Fortescue Storage in the ranges (pumped hydro) 1 2 3 4 5 6 7 Corridor 7 (proposed) DESERT SOLAR ZONE KIMBERLEY TOP END GULF N HOW THE PLAN WORKS 1 Northern flood rivers More than 200,000 GL a year runs to the sea, 94% of it as wet-season flood pulses. 2 Capture the flood only Target 30,000 GL a year, 12–15% of northern runoff. Dry-season flows are not touched. 3 Feeder aqueducts Elevated feeders carry the water to the nearest corridor. Lake Argyle is already built. 4 Corridors to the Alice Hub Every corridor carries water. Storage is central, at about 550 m, with storage in the ranges. 5 Inland floods Lake Eyre Basin floods are captured above the lake inlet and where corridors cross rivers. 6 Delivered by gravity From the Alice Hub the corridors carry water south. They link the ports and cities. 7 Towns in solar and farming rings A town every 100 km, in a solar PV ring with farming under it. Spurs link coastal towns. >200,000 GLnorthern runoff a year 30,000 GLcapture target a year ~550 mAlice Hub elevation KEY MMA corridor: every corridor carries water Feeder or storage link, with power line (indicative) Flood river (indicative course) Main river (indicative course) Capture site and pump station Storage in the ranges (pumped hydro) Flow to the Alice Hub Gravity delivery from the Alice Hub Town every 100 km: solar ring, farming under it City at a corridor intersection Port or capital city Corridors: the MMA national plan (spine, six corridors and Phase 0 spurs) plus proposed corridor 7. Water system: MMA Memo 14, The Sovereign Aqueduct Network. Towns: 150 drawn, one every 100 km along the seven corridors; 7 corridor intersections. Corridor 7 (Perth to Port Hedland, with coastal spurs) is proposed and indicative. River courses, capture sites and feeder routes are indicative. Storage in the ranges: placed on high ground read from an elevation map (MacDonnell Ranges, Hamersley Range, Queensland uplands), each linked to the nearest corridor. Indicative. High-level map. Route-by-route detail is on modernmovementaustralia.com.au. Not to scale.
Australia: the MMA plan. Every corridor carries water and links the ports and cities. Northern floods are captured and carried to the Alice Hub, with storage in the ranges, and delivered south by gravity. A town every 100 km stands in a solar PV ring with farming under the PV. Corridor 7, Perth to Port Hedland, is proposed. Rivers, feeders and storage positions are indicative. MMC-DWG-009-04. Not to scale.

MMA Memo 14: The Sovereign Aqueduct Network →

Water to the four desert zones.

The Vision: the four desert power zones →

Water for everything else on the line.

Towns

Domestic supply for every town on the corridor.

PV farming

Irrigation for the farmland under and around the solar.

Data centres

Cooling water for the AI data centres in the towns.

Hydrogen and industry

Process water for green hydrogen and industry.

Water harvesting is a proposal at pre-feasibility level: each site needs detailed hydrological, environmental and engineering assessment before it is built.1

References

  1. Murrell, B.B., MMA Memo 14: The Sovereign Aqueduct Network, Modern Movement Australia. modernmovementaustralia.com.au

Advantage: Water security →