MM Line · Aqueduct

Aqueduct.

Bulk water in a full-bay channel on MMC-VA — by gravity where the route can fall, roofed and pumped where it cannot.

The Line.

MMC-VA carries water on level 2 (19 m) in a channel that fills the full bay: 16.4 m wide by 6.4 m deep, about 105 m² of flow area. That is about 105 t of water per metre and about 2,624 t per 25 m span, the governing design load for MMC-VA.

The Line in Context.

Running full by gravity, the channel carries about 85 to 268 m³/s for gradients of 1 in 50,000 to 1 in 5,000: about 2,670 to 8,450 GL a year. At a gradient of about 1 in 3,600, or when pumped, it carries about 317 m³/s: about 10,000 GL a year, the planning figure for one MMC-VA line. These figures use Manning's equation with a concrete roughness of 0.013 (assumed) and ignore the pylon legs in the channel; gradient, lining and joints are detailed design.

Conventional bulk water pipelines are deployed at grade or shallowly buried, with substantial earthworks, environmental disturbance, and operational vulnerability to ground movement, flooding, and surface activities. Elevated pipeline support on a multi-modal corridor inherits the platform's productised modular construction economies and provides structural protection for the pipeline against the ground-level vulnerabilities that conventional pipelines suffer.

How Water Deploys on MMC.

The design allows for both options, chosen by terrain: an open aqueduct where the route can hold a continuous fall, or a closed channel with a roof, run as a pipe under pressure and pumped where it cannot. Channel wall panels stand each side on the level-2 deck slab, with a lining on the slab. The water adds mass to the structure, and an open surface can absorb motion as a tuned liquid damper does; the added mass also raises earthquake loads. Detailed design. On MMC-VB, water runs in a pipe under the freight deck: see Water.

The corridor's elevated geometry also provides natural pressure head where corridor terrain steps along the route, reducing pumping requirements and improving lifecycle energy economics for water transfer compared to at-grade pipelines that must follow ground topography. Single-service water viaducts are also supported for nations whose initial deployment is water-only.

Deployment, Illustrated.

The full-bay channel on level 2 of MMC-VA: 16.4 m wide by 6.4 m deep, about 105 t of water per metre. By gravity it carries about 2,670 to 8,450 GL a year for gradients of 1 in 50,000 to 1 in 5,000, and about 10,000 GL a year at 1 in 3,600 or when pumped. Open or roofed, by terrain.

MMC-DWG-006-11 Aqueduct
MMC-DWG-006-11 · Aqueduct. Rev A. Select to enlarge.

The Standardisation Case.

Aqueduct standardisation within the consortium framework covers channel section, wall panel and lining, joints, gradient and pumping, and water quality protocols, building on existing hydraulic and water infrastructure standards.

Patents Enabling This Line.

Foundation Core (P1), Integrated Foundation (P2), Architectural Framework (P4), Multimodal Viaduct Topside (P5).

See the full patent family →   Return to all MM Lines →