The Vision · Australia: Working Plan

Australia: the working plan in numbers.

The MMA plan for Australia, worked as an example of the MMC vision: 150 towns on seven corridors, the solar power they supply, the flood water harvested, the water stored, and the pumped hydro battery. Working figures; every assumption is listed in section 08.

Corridors, towns and water on one map.

Corridors
7

The seven MMA corridors, including corridor 7 from Perth to Port Hedland, plus the spine and spurs.

Towns
150

One every 100 km along the seven corridors, as drawn on MMC-DWG-009-04.

Intersection cities
7

Where the corridors cross, including the Alice Hub, Mount Isa and Kalgoorlie.

Flood capture
30,000 GL/yr

The MMA target, taken as flood overflow only.1

MMC WATER · AUSTRALIA: THE MMA PLAN NORTHERN FLOODS TO THE CENTRE · STORED AT THE ALICE HUB · DELIVERED SOUTH BY GRAVITY · CORRIDORS LINK THE PORTS AND CITIES Darwin Derby Port Hedland Perth Albany Esperance Adelaide Melbourne Sydney Newcastle Brisbane Mackay Port Douglas Karumba Canberra Geraldton Carnarvon Karratha Kalgoorlie Mount Isa Albury City 1 City 2 City 3 City 4 ALICE HUB · ~550 m Lake Argyle Fitzroy Ord Victoria Daly Roper Mitchell Gilbert Flinders Georgina Diamantina Cooper Creek Finke Lake Eyre Murray Darling Murrumbidgee Lachlan Burdekin Gascoyne Murchison Fortescue Storage in the ranges (pumped hydro) 1 2 3 4 5 6 7 Corridor 7 INNER CITIES KIMBERLEY TOP END GULF N HOW THE PLAN WORKS 1 Northern flood rivers More than 200,000 GL a year runs to the sea, 94% of it as wet-season flood pulses. 2 Capture the flood only Target 30,000 GL a year, 12–15% of northern runoff. Dry-season flows are not touched. 3 Feeder aqueducts Elevated feeders carry the water to the nearest corridor. Lake Argyle is already built. 4 Corridors to the Alice Hub Every corridor carries water. Storage is central, at about 550 m, with storage in the ranges. 5 Inland floods Lake Eyre Basin floods are captured above the lake inlet and where corridors cross rivers. 6 Delivered by gravity From the Alice Hub the corridors carry water south. They link the ports and cities. 7 Towns in solar and farming rings A town every 100 km, in a solar PV ring with farming under it. Spurs link coastal towns. >200,000 GLnorthern runoff a year 30,000 GLcapture target a year ~550 mAlice Hub elevation KEY MMA corridor: every corridor carries water Feeder or storage link, with power line (indicative) Flood river (indicative course) Main river (indicative course) Capture site and pump station Storage in the ranges (pumped hydro) Flow to the Alice Hub Gravity delivery from the Alice Hub Town every 100 km: solar ring, farming under it City at a corridor intersection Port or capital city Corridors: the MMA national plan (spine, seven corridors and Phase 0 spurs). Water system: MMA Memo 14, The Sovereign Aqueduct Network. Towns: 150 drawn, one every 100 km along the seven corridors; 7 corridor intersections. Corridor 7 (Perth to Port Hedland, with coastal spurs) is indicative. River courses, capture sites and feeder routes are indicative. Storage in the ranges: placed on high ground read from an elevation map (MacDonnell Ranges, Hamersley Range, Queensland uplands), each linked to the nearest corridor. Indicative. High-level map. Route-by-route detail is on modernmovementaustralia.com.au. Not to scale.
Australia: the MMA plan. MMC-DWG-009-04. Rivers, feeders and storage positions are indicative. Not to scale.

Water Harvesting →   Route detail on MMA →

Built outward in rings.

Each town is the centre of its own solar and farmland, built ring by ring.

  1. The town, 0 to 2 km. Built around a central square, with the corridor through the centre.
  2. Elevated PV with farming under it, 2 to 4 km. Panels raised about 5 m, so crops and machinery work underneath.
  3. PV at scale, 4 to 8.2 km. The main solar ring.
  4. CSP and wind, 8.2 to 9.4 km. The outer ring.
  5. The Australian hub, 6.7 GW. To reach 1,000 GW from 150 towns, each hub is 6.7 GW, about 267 km² of solar. The MMC standard hub is 5 GW, with its outer ring at 8.2 km.
  6. Expansion outward in rings. Each further ring adds about 5 GW and about 200 km². Towns are 100 km apart, so a 20 GW hub, 32 km across, leaves open country between towns.
Hub sizeOuter radiusSolar area a town150 townsEnergy a year at 24%
Australian hub, 6.7 GW9.4 km267 km²1,000 GW2,102 TWh
10.0 GW11.5 km400 km²1,500 GW3,154 TWh
15.0 GW14.0 km600 km²2,250 GW4,730 TWh
20.0 GW16.1 km800 km²3,000 GW6,307 TWh
2 km 4 km 8.2 km 9.4 km · 6.7 GW 11.5 km · 10 GW 14.0 km · 15 GW 16.1 km · 20 GW Town centre of the hub, 0–2 km Agrivoltaics crops and animals in the shade, 2–4 km PV rows of panels, 4–8.2 km CSP towers and wind outer ring, 8.2–9.4 km Australian hub: 6.7 GW rings to 9.4 km, ~267 km² PV expansion: +5 GW per ring east and west, along the corridor Farmland, either side of the city north and south, irrigated, past the PV Pumped hydro where the terrain suits MMC corridor to the next towns North–south transport link open lane through the town and farmland SCALE (ILLUSTRATIVE) Australian hub6.7 GW · 9.4 km PV expand to10 GW · 11.5 km 15 GW · 14.0 km 20 GW · 16.1 km Land per 5 GW~200 km² 150 hubs × 6.7 GW~1,000 GW At MMA density, ~40 km² per GW AUSTRALIA · WORKING PLAN Town hub 6.7 GW hub, PV and farmland expansion Concentric rings · farmland beyond the PV · illustrative Rev A · 23 Nov 2026 · BB (Boh Brett) Murrell
The Australian town hub, 6.7 GW, in rings to about 9.4 km, with expansion rings to 10, 15 and 20 GW. East and west, along the corridor, the PV expands ring by ring; north and south, irrigated farmland expands past the PV. Illustrative.

PV / Farming →   Cities →

1,000 GW from 150 towns.

One town
6.7 GW

About 267 km² of solar; about 14,016 GWh a year.A2

150 towns
1,000 GW

About 40,000 km² of solar in total.A1

Energy a year
~2,102 TWh

Range 1,927 to 2,278 TWh at capacity factors of 22 to 26%.2

Against today
7.4 times

Australia generated 283,920 GWh in 2024.4

QuantityFigureHow it is calculated
Capacity of one town6.7 GW1,000 GW ÷ 150 towns
Solar area of one town267 km²6.7 GW × 40 km² per GW
Energy from one town14,016 GWh a year6.7 GW × 8,760 hours × 24%
Capacity of 150 towns1,000 GW150 × 6.7 GW
Solar area of 150 towns40,000 km²1,000 GW × 40 km² per GW
Energy from 150 towns2,102 TWh a year1,000 GW × 8,760 hours × 24%; 1,927 TWh at 22%, 2,278 TWh at 26%

30,000 GL a year, lifted to the centre.

Harvested
30,000 GL/yr

About 12–15% of northern runoff, as flood overflow only.1

Energy to lift it
~53 TWh/yr

To the Alice Hub at about 550 m, at 85% pump efficiency.A4

Share of the solar
2.5%

Equal to the output of about 4 towns.

Pump power
~12 GW

If all pumping is done in the six flood months.A5

QuantityFigureHow it is calculated
Energy to lift 1 GL by 550 m1.50 GWh1,000 kg per m³ × 9.81 m/s² × 550 m × 1,000,000 m³ ÷ 3.6 × 10¹²
Energy to lift 30,000 GL, no losses44,962 GWh a year30,000 × 1.50 GWh
With pump losses52,897 GWh a year44,962 ÷ 0.85
Share of the solar output2.5%52,897 ÷ 2,102,400 GWh
Average pump power in the flood months12.1 GW52,897 GWh ÷ 4,380 hours

Pipe and channel friction over the length of the corridors is not included, so the pumping energy is a lower figure than the real one.

Storage at storage locations, not in each town.

About 0.98 GWh from every gigalitre at 400 m.

Stored water is also the battery. Surplus solar pumps it to the upper reservoir by day; it runs back through turbines when power is needed.

Per gigalitre
~0.98 GWh

Delivered at 400 m head and 90% generating efficiency.A6

16,000 GL at 400 m
~15,700 GWh

One full discharge of the Alice Hub volume at the 400 m average head.

One night, one town
~20 GL

Cycled to carry half of one town's daily output into the night.A7

One night, 150 towns
~2,900 GL

18% of the 16,000 GL. The water is reused each day.

QuantityFigureHow it is calculated
Energy in 1 GL at 400 m1.09 GWh1,000 × 9.81 × 400 × 1,000,000 ÷ 3.6 × 10¹²
Delivered by the turbines0.98 GWh per GL1.09 × 0.9
16,000 GL discharged once at 400 m15,696 GWh16,000 × 0.98 GWh
Half a day of output, one town19.2 GWh14,016 GWh ÷ 365 ÷ 2
Water cycled for one town-night19.6 GL19.2 ÷ 0.98 GWh per GL
Water cycled for 150 towns2,936 GL150 × 19.6 GL
Nights carried by 16,000 GL with no refill5.515,696 ÷ 2,880 GWh a night

The MMA Alice Hub memo uses an average head of 770 m for its seven gorge pairs and gives about 30,886 GWh usable.3 At 770 m the energy in 16,000 GL is 33,572 GWh before losses. This page uses the 400 m average across all storage locations.

The plan in one table.

ItemFigureBasis
Corridors7Seven MMA corridors
Towns150One every 100 km
Solar capacity1,000 GW6.7 GW a town; expandable in rings to 20 GW a town (3,000 GW)
Solar area40,000 km²40 km² per GW
Solar energy~2,102 TWh a year24% capacity factor; 7.4 times Australian generation in 2024
Water harvested30,000 GL a yearMMA Memo 14 target
Energy to lift the water~53 TWh a year2.5% of the solar energy
Water stored16,000 GLAlice Hub, MMA plan; range sites not yet sized
Battery, one full discharge~15,700 GWh400 m head, 90% efficiency
Water cycled each night~2,900 GLHalf of the daily solar output carried into the night

What the figures rest on.

  1. A1. Towns. 150 towns as drawn on MMC-DWG-009-04, each at 6.7 GW so the total is 1,000 GW. The MMC standard hub is 5 GW. The MMA plan states 200 towns at 5 GW; the MMA site is to be updated.
  2. A2. Solar density and yield. 40 km² per GW and a capacity factor of 22 to 26%, mid 24%, from the MMA solar sizing memo.2 Applied to the whole hub; CSP and wind are not sized separately. The split of the Australian hub into a PV ring to 8.2 km and a CSP and wind ring to 9.4 km is illustrative.
  3. A3. Harvest. 30,000 GL a year, the MMA Memo 14 target.1
  4. A4. Lift. All water is lifted 550 m, from near sea level to the Alice Hub, at 85% pump efficiency. Friction is not included. Inland capture starts higher and needs less lift.
  5. A5. Pumping season. All pumping is done in six months (4,380 hours), November to April.
  6. A6. Pumped hydro. Average head 400 m across the storage locations; 90% generating efficiency. Storage volume 16,000 GL, from the MMA Alice Hub memo.3
  7. A7. Night supply. Half of each day's solar output is stored and delivered at night. The real share depends on demand, wind and CSP.
  1. MMA Memo 14, The Sovereign Aqueduct Network.
  2. MMA memo, Solar sizing.
  3. MMA memo, Alice Hub pumped hydro.
  4. Department of Climate Change, Energy, the Environment and Water, Australian Energy Statistics, Table O, calendar year 2024.